Haier HSU-09HS03/R2DB Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Aparelhos de ar condicionado "split system" Haier HSU-09HS03/R2DB. Haier HSU-09HS03/R2DB User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - SERVICE MANUAL

Domestic Air Conditioner SERVICE MANUAL Models HSU-12HS03/R2( DB) HSU-09HS03/R2( DB) l Features l Comfortable:wide-angle airflow l he

Página 2

Curves of compressor performanceCompressor:DA89XIC-20FZModel:HSU-09HS03/R2(DB)358.3Ambient temp OCUNDER COOL OCSUCTION GAS TEMP OC356.55.53.5120010008

Página 3 - & SERIES INTRODUCTION

SERIAL NUMBER 1 2 3 4 5 6 7FREQUENCY 3050608090110120INPUT POWER 1244 2321 2833 3983 4502 5565 6246SERIAL NUMBER 1 2 3 4 5 6 7FREQUENCY 30506080901101

Página 4 - Introductory Remarks

Description,dimension and function ofmain components and accessories12 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 5 - C.Series brief introduction

13Outdoor unitINLETOUTLET DRAIN HOSECONNECTING PIPING AND ELECTRICAL WIRING Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 6 - Specifications

760285Fresh air conditioner NET DIMENSIONS FOR INDOOR UNITModels: HSU-12HS03/ R2(DB) HSU-09HS03/R2(DB) NET DIMENSIONS FOR OUTDOOR UNIT1484

Página 7

Knock-down drawingsDomestic Air Conditioner Model: HSU-12HS03/R2(DB) 15 HSU-09HS03/R2(DB)

Página 8

16Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 9

No. inexplodedviewSpare partsnumberSpare parts descriptionin englishQTY. Model Price list FailurerateThe proportionof the sparepart stockremark1 001A1

Página 10 - DA89X1C-20FZ

No. inexplodedviewSpare partsnumberSpare parts descriptionin englishQTY. Model Price list Failure rateThe proportionof the sparepart stockremark1 001A

Página 11 - COMPRESSOR:C-6RZ092H1A

KNOCK-DOWN DRAWINGS FOR OUTDOOR UNIT(HSU-09/12HS03/R2(DB))21172345691113181920222310178121516142428293025262719 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(D

Página 12 - Domestic Air Conditioner

Content 1. Description of product model coding and series introduction--3 2. Specifications ----------------------------------------------------------

Página 13 - OUTLET DRAIN HOSE

No. inexploded viewSpare partsnumberSpare parts description in english Model QTY.FailurerateThe proportionof the spare partstockremark1 001A0100017 Fr

Página 14 - HSU-12HS03/R2(DB)

No. inexplodedviewSpare partsnumberSpare parts description in english Model QTY.FailurerateThe proportionof the sparepart stockremark1 001A0100017 Fro

Página 15 - Knock-down drawings

22Brief introduction to electrical control functions Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 16

1. Application Range This function guide can be used for the HSU-09HS03/R2(DB) air-conditioners and othe

Página 17 - Edition:2004/10/26

and medium of wind volume when it is under heating mode. Modification index table for set temperature Mode Content of modification Modified varia

Página 18

Cooling deviation to zero Moisture removing deviation to level G Heating deviat

Página 19

The maximum frequency value refers to the max value listed above. The maximum and minimum values for cooli

Página 20

Frequency control form for wind volume Limited frequency variables Limited frequency Medium wind volume

Página 21 - Edition:2004/09/20

3-1.heat running 3-1-1. Warm boot When the heat running starts or the frost removing ends and the compr

Página 22 - control functions

Refer to the temperature level control function 3-1-4. Frost-removing operation . The blower stops after

Página 23

DESCRIPTION OF PRODUCT MODEL CODING & SERIES INTRODUCTION 3Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 24

. Change the set temperature. With temperature adjusting function . The wind volume is the automatic mediu

Página 25

will 3 minutes of idle mode. If the compressor senses the incoming wind temperature is higher than 23 aft

Página 26

according to the heat-exchange temperatures as shown in the table below. High Work-intense protection cont

Página 27

receives wrong EEPROM signals from the outdoor unit. . In this case the control and emergency operation ar

Página 28

Chapter I: Indoor Unit and Main board for Outdoor Unit Notice: During operations under any mode, if short circuit, open circuit and other malfunct

Página 29

4.Heating mode 4.1.The four-way valve is electrified 2 seconds after the compressor is electrified 4.2.Malfunctions of the discharge temperature sens

Página 30

halts during the defrosting stage, remain still for 30 seconds, then conducts defrosting operation if it is still within the defrosting stage, the com

Página 31

and the outdoor fan motor returns to its original state; The above temperature points, frequency-decreasing step and time interval can all be adjusted

Página 32

Wiring diagram38 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 33

W WHITEY/G YELLOW/GREENB BLACKR REDINDOOR UNIT DIAGRAMFAN MOTORPOWER SUPPLYBR BROWNBL BLUEARE OPTIONALHAS NOT 2NOTES THE PARTS OF DOTTED 1

Página 34

4Introductory Remarks Description of coding rules of unit modelCoding rules and descriptions are as follows:Applicable frequency:0(50HZ),1(60HZ)Applic

Página 35

B BLACKBL BLUER REDW WHITEY/G YELLOWOR ORANGE/GREENGR GRAYBLCN11CN10CN9SPDUCN10OR21 The capacitor retains high voltage even after the plug-of

Página 36

CIRCUIT DIAGRAM41 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 37

Domestic Air Conditioner HSU-12HS03/R2( DB) Model:HSU-09HS03/R2( DB) INDOOR UNIT 1 2 3 4

Página 38 - Wiring diagram

Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner OUTDOOR UNIT:43

Página 39 - INDOOR UNIT DIAGRAM

ABNORMITY DIAGNOSE 44 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 40

Malfunction explanation Error symbals Anomaly Running Heating Cooling Indoor Outdoor Automatic restore Causes Indoor thermister anomaly ★

Página 41 - CIRCUIT DIAGRAM

Overheat protection for exhaust temperature ★ * 1.The system is lack of air or overloaded with air 2.The voltage is too high (over 242V

Página 42 - INDOOR UNIT

Module temperature increase protection □ ★ ★ * 1.Check if there are seizes in the compressor 2.。 3.If there are any damages of power modul

Página 43

.LED output: Twinkling times of LED Possible cause of the malfunction 1 Outdoor temperature sensor abnormity 2 Outdoor defrosting sensor abnormity 3

Página 44 - ABNORMITY DIAGNOSE

TROUBLE SHOOTING49 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 45

No.123Operating conditionNorminal coolingNorminal heatingNorminal electricalheatingindoor air statusDBOC WBOC20OC Not controlDBOC WBOC7OC 6OCoutdoor a

Página 46

50 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 47

REFRIGERATING CYCLE DIAGRAM Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner 51

Página 48

Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner Refrigerating cycle diagram52

Página 49 - TROUBLE SHOOTING

Noise level test chart and air velocity distribution53 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 50

Noise level test chart and air velocity distributionNoise level test chart010203040506063Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz0102030405060

Página 51 - REFRIGERATING CYCLE DIAGRAM

55Noise level test chart and air velocity distributionAir velocity distributionmFig 1top viewflow control panel horizallourer:centerFig 3top viewflow

Página 52

Installation manual56 Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner

Página 53

No.Installation Manual of Room Air ConditionerRead this manual before installation.Explain sufficiently the operating means to the useraccording to th

Página 54 - Noise level test chart

Floor fixing dimensionsof the outdoor unit(Unit:mm)Fixing of outdoor unitIf vibration may affect the house, fix the unit by attaching a vibration-proo

Página 55 - Air velocity distribution

Int1 Fitting of the Mounting Plate and Positioning of the Wall Hole2 Making a Hole on the Wall and Fitting the Piping Hole CoverWhen the mounting plat

Página 56 - Installation manual

SpecificationsModel:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Domestic Air Conditioner 6

Página 57 - Remote controller

Indoor Unit3 Installation of the Indoor UnitDrawing of pipeRear pipingDraw pipes and the drain hose, then fasten them with the adhesive tapeLeft Le

Página 58 - Selection of Pipe

YEL/GRNYEL/GRNWHTBLKREDREDBLKWHTIndoor unitIndoor unitOutdoor unitWhen connecting the cable after installing the indoor unitWhen connecting the cable

Página 59

Outdoor Unit1 Installation of Outdoor Unit 2 Connection of Pipes3 Connection4 Attaching Drain-ElbowInstall according to To bend a pipe, give the round

Página 60 - Indoor Unit

Outdoor Unit5 Purging Method: To use vacuum pumpOpen the handle at low in gaugemanifold, operatevacuum pump. If the scale-moves of gause (low)reach va

Página 61 - Indoor unit

1.Cut pipe3.Insert the flare nut4.Flare pipe2.Remove burs0~0.5mm 1.0~1.5mm 1.5~2.0mmFlare tool for R410AClutch-typeConventional flare toolclutch-type(

Página 62 - Outdoor Unit

Sincere Forever Haier Group Haier Industrial Park, No.1, Haier Road 266101, Qingdao, China http://www.haier.com

Página 63

7Cooling capacity:Cooling coefficient:Cooling power input:Moisture removalOperating voltage rangeOperating temp. rangeVariation of temp. adjustClimate

Página 64 - 3 On Drainage

8Cooling capacity:Cooling coefficient:Cooling power input:Moisture removalOperating voltage rangeOperating temp. rangeVariation of temp. adjustClimate

Página 65 - Sincere Forever

Curves of performance of compressor9Curves of performance of compressorCurves of performance of compressor Model:HSU-12HS03/R2(DB)HSU-09HS03/R2(DB)Dom