BD-478A
Freezer
Service Manual
Features
Door lock for safety storage
High pressure foam cover for efficient Temperature
preservation.
Adjustable thermostat.
Superior insulation.
Efficient defrosted storage
Designed for cafeterias restaurants and hotels
Haier Group
Manual No.:BD-478A Edition:20051201
BD-478A
PDF created with pdfFactory trial version www.pdffactory.com
Vista de página 0
1 2 3 4 5 6 ... 60 61

Resumo do Conteúdo

Página 1 - Service Manual

BD-478A Freezer Service Manual ●Features ●Door lock for safety storage ●High pressure foam cover for efficient Temperature preservation. ●Adjus

Página 2 - Contents

9INSTALLATION AND ACCESSORY PARTS Installation and Accessory Parts l Do not over fill freezer for proper internal air circulation. Electrical Requi

Página 3 - C D

10Operating Your Freezer INSTALLATION AND ACCESSORY PARTS Installation and Accessory Parts Once the freezer is in its proper place, plug it in an e

Página 4 - Features

11INSTALLATION AND ACCESSORY PARTS Installation and Accessory Parts Food Storage Basket Your Freezer has 1 or 2 removable basket. It allows you to

Página 5 - Specifications

12 SYSTEM FLOW CHART System Flow Chart The refrigeration system of direct cooling single-system freezers belongs to the category of a

Página 6 - Safety Precautions

13 FUNCTION SCHEDULE Function Schedule Set the temperature, on the temperature contrail knob.”1”being the warmest and “6”being the coldest. Init

Página 7

14 CIRCUIT DIAGRAM Circuit Diagram Brief description of principle about BD-318A/428A: Brief description of principle about Thermostat: Wh

Página 8 - Net Dimension

1512.1.1 Servicing freezer (1)Check the whole circuit of freezer, if there are wire connections came off, any wires broken, or a short circuit. (

Página 9 - Adjusting Your Freezer

16(1) Leakage of compressor: mainly because of serious vibration, the motor coil of compressor contacts with the shell, the coat of enameled wire w

Página 10

17tetra chloromethane or alcohol to clean it. If the leakage occurs in the inner of compressor, it needs to be changed. (3) Leakage of temperature

Página 11 - Operating Your Freezer

18(1) At normal operation conditions, the temperature around the surface of freezer evaporator is nearly the same; the thickness of frost layer is

Página 12 - Food Storage Basket

1 Contents 1. Contents……………………………………………………………………….……1 2. Product Code Illumination and Series Introduction…………………………… 2 3. Features ……………………………………

Página 13

19normal running sounds. If there is heavy buzz that means the motor has not been started normally. If there is bump sound, this means that the sus

Página 14 - Function Schedule

20please move your hand over it quickly, otherwise your hand will be stuck. (4) At normal operation of freezer, the temperature of filter dryer cov

Página 15 - 12.1 System Trouble shooting

21(2) If noise is caused by tighten loose of screw between the base cover and freezer body, please make it tight. (3) If the reason for noise is th

Página 16

22near thermal source or not; if the room temperature is too high or not; if the condenser is blocked by cloth pieces or paper or dirt or not. Any

Página 17

23not effective, take a piece of sponge with about 10mm wide, 5mm thick, a little longer than the seam and put it inside the seal bar, i.e., the pl

Página 18

24Problems Reasons Removing methods Compressor can not be started 1. Fuse is broken 2. The contact of plug, socket, and cable is not good. Cab

Página 19

25repeatedly. change. After short time of operation, over load protection unit cuts off 1. The voltage is too high. 2. Over load protection unit i

Página 20

26The fan doesn’t run 1. Check if any connection has come off. 2. Check is the fan is burned. 1. Change the fan. 2. Change the fan. Electricity le

Página 21 - 12.1.6 System noise repair

27(1) Switch off power. (2) Remove side protection cover. (3) Unscrew fastening nut. (4) Hold the base end of temperature sensing tube and the cont

Página 22

28bad thermal protection unit is normally caused by burn contact points or a bad heating wire. ⑤ The motor winding are burned. ⑥ The compressor sha

Página 23

2PRODUCT CODE ILLUMINNATION AND SERIES INTRODUCTION Product Code Illumination and Series Introduction B D -- □ □ A B C D

Página 24

29several minutes later it starts again and stops automatically again. With in cycles like this and the motor, or starter, and thermal protection u

Página 25

30(1) Operation method of repairing equipment (please see instruction manual). (2) Special requirements ① The time interval from opening of compre

Página 26

31(5) Remove the compressor. (6) Install new compressor and new filter dryer and weld them. The open time of system shall not be more than 10 min.

Página 27

32(4) When seal plug of compressor is removed, if there is no gas flowing sound (no pressure), the compressor shall not be used. (5) Compressor has

Página 28

33greater than 45°, so that the sliding door could not move out from its guiding slot and other accident will not happen. (2) The clearance between

Página 29

34(10) Cold drinks and snacks, which contain much milk and needs to be stored at low temperature, please try to put them at lower part of freezer.

Página 30

35electricity consumption. (1) At a regular period, when the frost layer reaches about 5mm, please remove it by plastic shovel. (2) When removing

Página 31

36condenser, fan, compressor and temperature controller. Wipe clean and avoid damaging pipes and electrical parts. (2) Switch on power and check th

Página 32

3712.5.1 Freezer repair tool and equipment (1) Recovery machine (2) N2 container, O2 container, acetylene container and torch kit. (3) Thermometer.

Página 33 - 12.4.2 Notice for use

38(2) Please keep the pliers, pipe cutting unit and Hansen valve clean, and keep them away from grease dirt. 12.5.3 Procedure for filling equipment

Página 34

3FEATURES Features ●Door lock for safety storage ●High pressure foam cover for efficient Temperature preservation. ●Adjustable thermostat. ●Sup

Página 35 - 12.4.4 Maintenance

39(3) Filling ① Determine the filling quantity first according to the freezer being repaired. (Each small mark of the liquid tube is 25g, each big

Página 36

40Freezer noise mainly comes from the compressor. The Compressor generates various sounds. There are continuous and not continuous, periodic and no

Página 37

41Compressor parts, such as compressor body, exhaust tube, noise eliminator in compressor, supporting spring, etc., will cause resonance sometimes

Página 38 - 12.5.2 Notice for use

42At operation of compressor, it breathes in and exhausts out gas continuously. When liquid refrigerant flows through capillary, there will be gas

Página 39

43sometime? Answer: After half a year or one year’s use, clearance will increase because of wear of inner components, and compressor’s noise will i

Página 40 - 12.6 Freezer noise

44Answer: This is because the affection of freezer noise to people is relative to the level of environmental sound. In noisy city or shops, people

Página 41

45(2) Put freezer onto 5-10mm elastic cushion. (3) Freezer must be empty and running at least 30 minutes before measuring. If normal stop happens,

Página 42 - 12.6.4 Gas flowing sound

46approximate value of sound power level. The restriction to noise in national standard is more strict and scientific. At present, freezer noise is

Página 43

47(3) When freezer stops, the compressor decelerates, high pressure and low pressure at gas exhausting tube and returning tube will get balance, th

Página 44

48Answer: Normally speaking, freezer noise within the range of national standard is normal. But if there is continuous sound of metal contacting fr

Página 45

4SPECIFICATIONS Specifications Model BD-388A BD-478A Capacity (L) 388 478 Power Supply (V/Hz) 220V~ /50Hz 220V~ /50Hz Unit Dimension (W*D*H) 1

Página 46

49empty. Turn the knob of temperature controller to middle or near to strong position and close the door or cover. Make the measurement at least 30

Página 47

50A=l1/2 +d b=l2/2 +d c=l3/2 +d Take d=1m Then S=4(ab+bc+ac) The positions of measuring points are shown in table 4. 12.8Measuring technology of

Página 48

51temperature with load. Type tests include items (1), (2), (8), (9), (10), (13), (17), (18), (20), (21) and the followings: (22) total effective v

Página 49

52voltage is 1650V (50Hz) for 2s. At the test, there will not flashover and breakdown occurring. 12.8.2.4 Ground resistor Check the voltage drop be

Página 50

53material of enclosure structure of test room is made up of 10mm thick polyurethane or polystyrene, which has good insulation. There are air re-tr

Página 51

54 Dimensions (mm) Mass (g) Note Small Middle Big 25×50×100 50×100×100 50×100×200 125 500 1000 In the geometrical center of 5oog pack, there is a

Página 52 - 12.8.2.2 Insulation resistor

55sensing parts of thermometers, and put the bottom end of gauze into distilled water) under the blowing of wind with the speed of 2.5-3m/s. Record

Página 53

56types 25℃; T type 32℃. Test time is 24h. The consumption of storage freezer and storage and freezing freezer shall be less than 115% of rated; fr

Página 54

57 Marketing model: BD-388A/478A Exploded ViewEdition:2005 12 01CARTONUSER MANAUL

Página 55

58No. Spare parts number Spare parts description in english Model QTY. Price list Failure rate the proportion of the spare-part stock Remark 1 007

Página 56

5SAFETY PRECAUTIONS Safety Precautions Read all of the instructions before using this appliance. When using this appliance, always exercise basic s

Página 57 - Exploded View

5928 0070202885 Panel control BD-388A/478A 1 0 0 X 29 0075040013 Thermostat BD-388A/478A 1 0.392% 0.600% * 30 0072070010 Thermostat prote

Página 58 - USER MANAUL

6063 0075080006 Lamp switch BD-388A/478A 1 0.010% 0.020% * 64 0075120011 Lamp BD-388A/478A 1 0.010% 0.020% * 65 0077050051 Screw BD-388A/4

Página 59

6SAFETY PRECAUTIONS Safety Precautions 7. This freezer should not be recessed or built-in an enclosed Cabinet. It is designed for freestanding in

Página 60

7NET DIMENSION Net Dimension HaLWH Model BD-388A BD-478A Unit Dimension (W*D*H) 1420*715*810 1690*715*810 Dimension (Door open) 1420*715*147

Página 61

8INSTALLATION AND ACCESSORY PARTS Installation and Accessory Parts Unpacking Your Freezer 1.Remove all packaging material; this includes the foam b

Comentários a estes Manuais

Sem comentários